Double-decker stands where extra space begins with engineering.

ALLEXPO develops two-storey exhibition projects around the venue, structural requirements, escape routes, upper-floor function and the complete build sequence — not only the visual concept.

Double-decker stands where extra space begins with engineering. — ALLEXPO
More usable spaceMeeting or hospitality areas above
Approval-led planningVenue rules checked before design commitment
Structural coordinationLoads, stairs, guarding and documentation
Full site sequenceTransport, installation, inspection and dismantling

01 — SCOPE

When does a double-decker exhibition stand make sense?

A second level is useful when additional meeting, hospitality or staff space creates more value than the engineering, approval and venue costs it introduces.

Permission is venue- and event-specific. Hall height, stand area, upper-floor use, occupancy, stairs, escape routes, fire protection and structural calculations must be checked before a layout is treated as approved.

02 — DELIVERABLES

A two-storey stand is an architectural and compliance project.

01

Feasibility

Hall, organiser, height, footprint and upper-floor use reviewed first.

02

Structural package

Load concept, stairs, balustrades, drawings and required calculations.

03

Fire and escape planning

Occupancy, routes, signage and venue-specific safety measures.

04

Controlled delivery

Production, transport, staged installation, inspection and dismantling.

03 — PROCESS

Approval milestones shape the schedule.

01

Venue check

Confirm whether two-storey construction is permitted for the hall and event.

02

Use and occupancy

Define who uses the upper level and how people enter and leave it.

03

Engineering

Develop structure, stairs, guarding, loads and technical documentation.

04

Submission and production

Submit the required package and release production against approvals.

05

Installation and inspection

Build in sequence and coordinate required site checks before handover.

04 — COST

What adds cost to a double-decker stand?

The upper-floor area, steelwork, stairs, guarding, structural review, fire measures, longer installation, lifting and venue fees sit above the normal stand-build scope.

The custom-stand benchmark of €300–€800+ per m² net is only a starting reference for the base project. Upper-storey construction, engineering and organiser charges must be calculated separately.

Budget structure · base stand + upper level + approvalsStart earlier than a single-storey project; every venue and event sets its own submission deadlines.

Scope can include

  • Architecture and production documentation
  • Structural coordination and approval package
  • Transport, installation, handover and dismantling

Usually third-party or organiser costs

  • Structural inspection and approval fees
  • Fire-watch, sprinkler, utility or lifting services required by the venue
  • Exhibition floor-space and upper-level organiser charges
Estimate a double-decker stand
Double-decker stands where extra space begins with engineering. — ALLEXPO project

05 — SELECTED WORK

Selected projects

Portfolio
CIRCLE Fitness custom stand — Berlin
01

Berlin

CIRCLE Fitness custom stand

60 m² · demo zones · LED · meeting area
Hospitality & brand space — Poznań
02

Poznań

Hospitality & brand space

Scenography, light, bar construction and technical support.
Large-format hospitality stand — Warsaw
03

Warsaw

Large-format hospitality stand

Guest zone, graphics and integrated multimedia.
Beauty & medical custom stand — Milan
04

Milan

Beauty & medical custom stand

45 m² · product demo · LED · client area
Temporary event pavilion — Poland
05

Poland

Temporary event pavilion

Structure, interior fit-out, logistics and dismantling.

06 — FAQ

Questions before planning a second level.

Can every exhibition hall accept a double-decker stand?

No. Permission depends on the hall, event, construction height and organiser rules. Feasibility must be confirmed before design approval.

What documents are normally required?

Requirements vary, but dimensioned plans, sections, structural calculations, material information and escape-route documentation are common.

How early should the project start?

Earlier than a single-storey stand. For example, Messe Frankfurt asks for specified approval documents no later than six weeks before setup, but the applicable event rules must always be checked.

What should go on the upper floor?

Usually controlled-access meeting, hospitality or staff functions. The intended occupancy directly affects stairs, escape routes and safety planning.

READY WHEN YOU ARE

Your next stand starts with a clear brief.

Share your goals, venue and timing. We will review the scope and return with practical next steps.

Open the 7-step Brief